HIANDRI Approved Bracing Systems

HIANDRI can be used with the following systems

Winstone Wallboards

GIB EzyBrace Systems

Carter Holt Harvey

Ecoply bracing & ecoply barrier bracing systems

Gamma Bracing Technologies

Gamma Bracing

Independent Building Supplies

IBS OS'BraceRAP bracing system

Elephant Plaster board

Elephant Plasterboard QuickBrace©

Masons Plastabrick LTD

Barricade Weather Defense System

Remember

When using your selected bracing system, you must follow the installation instructions for that system.
frequently asked questions

Do you have a specific question in mind? Have a look at our FAQs as your query may have already been answered by our team there

Technical Assistance

Download our Installation Guide or speak to Sam, our specialist located in New Zealand

SAVING KIWI BUILDERS THOUSANDS

Our CodeMark approved system rasies the frame above the slab, protecting bottom plates from moisture, eliminating the need for DPC, and allowing drainage preventing costly wet frame delays.

The HIANDRI system has been fully engineered to satisfy the requirements of NZS3604:2011, NZS1170:2002, NZ AS1720.1:2022 their amendments and the Building Code. More importantly HIANDRI packers have CodeMark Certification and are BRANZ appraised. Submitting the CodeMark Certificate and Installation Instructions to the Building Consent Authority (BCA) is an acceptable solution.

How much weight can one packer hold?
Under NZS3604, a single stud can only take a load of 10kN. HIANDRI Packers have been compression tested and fail at over 40kN or 4 Tonne.
NO, there is no load on the plate between the studs so there is no reason for the plate to sag. HIANDRI Packers are made from Polypropylene, it is called the steel of plastics; it is very hard and strong and capable of carrying at least 4 times the load that a stud can carry.

YES, however the bottom plates must be fixed using 125mm long Type 17 Buildex 14gauge Bugle head screws – Refer to ‘Installation Manual’.

YES. It can be installed in any location permitted under NZS3604 and NZS1170 and their amendments.
NO. You should place a packer only under every stud at either 400mm or 600mm centres, and also additional packers at all point loads and lintel studs. However, you only require a single packer for double studs for internal doors and a single packer for stud/block/stud situations (ie. Wall intersections) – Refer to ‘Installation Instructions.’

Certifications

Codemark Certificate
Branz Appraisal

Installation Manual

The easy fix for drier frames tag line here

The HIANDRI system has been fully engineered to satisfy the requirements of NZS 3604:2011, NZS 1170:2002, NZS AS 1720.1:2022 their amendments and the Building Code. More importantly HIANDRI packers have CodeMark Certification and are BRANZ appraised. Submitting the CodeMark Certificate and Installation Instructions to the Building Consent Authority (BCA) is an acceptable solution.

Installation Instructions

Acceptable layouts & orientation of HIANDRI packers, for timber and concrete floors.

Fixing Bottom Plates

Further details on fixing bottom plates on concrete and timber floors.

Bracing

Refer to our currently approved bracing systems and recommendations for fixings.

Trusted by builders like you

GENUINE FEEDBACK from real builds